Learn about Mu2e-II: Difference between revisions

From New MediaWiki Site
Jump to navigation Jump to search
No edit summary
No edit summary
Line 31: Line 31:
|-
|-
| || 650 || MHz
| || 650 || MHz
|-
| Operation || 40 || wk/yr
|-
| Up time || 90 || %
|-
|-
!colspan="3" |Mu2e-II parameters
!colspan="3" |Mu2e-II parameters
Line 36: Line 40:
| Bunch frequency || 81.25 || MHz (assumes 1/2 of 162.5 available)
| Bunch frequency || 81.25 || MHz (assumes 1/2 of 162.5 available)
|-
|-
| Run time/yr || 2<math>\small{\times 10^{7}}</math> || s
| Calibration, background, special runs || 30 || %
|-
| CE data || 70 || %
|-
| Mu2e-II efficiency || 100 || %
|-
| CE run time/yr || 1.5<math>\small{\times 10^{7}}</math> || s
|-
|-
| Duration of run || 3 || yr
| Duration of run || 4 || yr
|-
|-
| Total run time || 6<math>\small{\times 10^7}</math> || s
| Total run time || 6<math>\small{\times 10^7}</math> || s

Revision as of 21:39, 13 September 2021

Nominal Parameter values
Parameter Nominal value Units, Comments
PIP-II parameters
Beam energy (kinetic) 800 MeV
1.28[math]\displaystyle{ \small{\times 10^{-10}} }[/math] J
Particles/pulse 6.7[math]\displaystyle{ \small{\times 10^{12}} }[/math]
I_average in pulse 2 mA (5 mA peak)
Pulse length 550 [math]\displaystyle{ \small\mu }[/math]s
Pulse rep rate 20 Hz
Bunch pattern programmable
Peak bunch size 2[math]\displaystyle{ \small{\times 10^8} }[/math] (5 mA)
Bunch length 4 ps
RF frequency 162.5 MHz
325 MHz
650 MHz
Operation 40 wk/yr
Up time 90 %
Mu2e-II parameters
Bunch frequency 81.25 MHz (assumes 1/2 of 162.5 available)
Calibration, background, special runs 30 %
CE data 70 %
Mu2e-II efficiency 100 %
CE run time/yr 1.5[math]\displaystyle{ \small{\times 10^{7}} }[/math] s
Duration of run 4 yr
Total run time 6[math]\displaystyle{ \small{\times 10^7} }[/math] s
Total linac reps 1.2[math]\displaystyle{ \small{\times 10^{9}} }[/math]
Extinction 1[math]\displaystyle{ \small{\times 10^{-11}} }[/math] [1[math]\displaystyle{ \small{\times 10^{-13}} }[/math] for 100x safety margin]
Beam power 120 kW (100 kW nominal)
Number of bunches/spill 8 (at 81.25 MHz)
Spill width 100 ns
Production target parameters
Material
Power deposition kW
Optimizable parameters for stopping target material
Aluminum stopping target
Spill period 1693 ns
Spills/linac rep 27770 approximate, at 20 Hz linac repetition rate
Protons/spill 1.6[math]\displaystyle{ \small{\times 10^{9}} }[/math] (5 mA)
POT 5[math]\displaystyle{ \small{\times 10^{22}} }[/math]
Stopped mu/p 1.9[math]\displaystyle{ \small{\times 10^{-4}} }[/math] rough estimate, TBC, assumes stopped mu/kW same at 800 and 8000 MeV among possibly other things
SES <3[math]\displaystyle{ \small{\times 10^{-18}} }[/math]
E(conversion e-) 104.97 MeV
tau(muon) 864 ns
Lead stopping target
E(conversion e-) 94.9 MeV
Tracker
Resolution at 100 MeV
Calorimeter
Material
Energy resolution 5% % (FWHM/2.36)
Time resolution < 500 ps
Position resolution 10 mm
Radiation dose 10 kGy/yr
[math]\displaystyle{ \small 1\times 10^{13} }[/math] n/cm[math]\displaystyle{ \small{^2} }[/math] (total 1 MeV equivalent)
Cosmic Ray Veto
Trigger/DAQ
Event size 1 MB
Tape storage 14 PB/yr