Learn about Mu2e-II: Difference between revisions

From New MediaWiki Site
Jump to navigation Jump to search
No edit summary
No edit summary
Line 10: Line 10:
| Beam energy (kinetic) || 800 || MeV
| Beam energy (kinetic) || 800 || MeV
|-
|-
| || 1.28e-10 || J
| || 1.28<math>\small{\times 10^{-10}}</math> || J
|-
|-
| Particles/pulse || 6.7e12 ||
| Particles/pulse || 6.7<math>\small{\times 10^{12}}</math> ||
|-
|-
| I_average in pulse || 2 || mA
| I_average in pulse || 2 || mA
|-
|-
| Pulse length || 550 || micro s
| Pulse length || 550 || <math>\small\mu</math>s
|-
|-
| Pulse rep rate || 20 || Hz
| Pulse rep rate || 20 || Hz
Line 30: Line 30:
!colspan="3" |Mu2e-II parameters
!colspan="3" |Mu2e-II parameters
|-
|-
| Run time/yr || 2e7 || s
| Run time/yr || 2<math>\small{\times 10^{7}}</math> || s
|-
|-
| Duration of run || 3 || yr
| Duration of run || 3 || yr
Line 36: Line 36:
| Total run time || 6e7 || s
| Total run time || 6e7 || s
|-
|-
| Total linac reps || 1.2e9 ||
| Total linac reps || 1.2<math>\small{\times 10^{9}}</math> ||
|-
|-
| Extinction || 1e-11 ||
| Extinction || 1<math>\small{\times 10^{-11}}</math> ||
|-
|-
| Beam power || 100 || kW
| Beam power || 100 || kW
Line 54: Line 54:
| Spills/linac rep || 27770 || approximate, at 20 Hz linac repetition rate
| Spills/linac rep || 27770 || approximate, at 20 Hz linac repetition rate
|-
|-
| Protons/spill || 1.4e9 ||
| Protons/spill || 1.4<math>\small{\times 10^{9}}</math> ||
|-
|-
| POT || 4.67e22 ||
| POT || 4.67<math>\small{\times 10^{22}}</math> ||
|-
|-
| Stopped mu/p || 1.9e-4 || rough estimate, TBC, assumes stopped mu/kW same at 800 and 8000 MeV among possibly other things
| Stopped mu/p || 1.9<math>\small{\times 10^{-4}}</math> || rough estimate, TBC, assumes stopped mu/kW same at 800 and 8000 MeV among possibly other things
|-
|-
| SES || <3e-18 ||
| SES || <3<math>\small{\times 10^{-18}}</math> ||
|-
|-
| E(conversion e-) || 104.97 || MeV
| E(conversion e-) || 104.97 || MeV

Revision as of 19:08, 14 August 2020

Nominal Parameter values
Parameter Nominal value Units
PIP-II parameters
Beam energy (kinetic) 800 MeV
1.28[math]\displaystyle{ \small{\times 10^{-10}} }[/math] J
Particles/pulse 6.7[math]\displaystyle{ \small{\times 10^{12}} }[/math]
I_average in pulse 2 mA
Pulse length 550 [math]\displaystyle{ \small\mu }[/math]s
Pulse rep rate 20 Hz
Bunch pattern programmable
RF frequency 162.5 MHz
325 MHz
650 MHz
Mu2e-II parameters
Run time/yr 2[math]\displaystyle{ \small{\times 10^{7}} }[/math] s
Duration of run 3 yr
Total run time 6e7 s
Total linac reps 1.2[math]\displaystyle{ \small{\times 10^{9}} }[/math]
Extinction 1[math]\displaystyle{ \small{\times 10^{-11}} }[/math]
Beam power 100 kW
Optimizable parameters for stopping target material
Aluminum stopping target
Number of bunches 16 (at 162.5 MHz)
Spill width 100 ns
Spill period 1693 ns
Spills/linac rep 27770 approximate, at 20 Hz linac repetition rate
Protons/spill 1.4[math]\displaystyle{ \small{\times 10^{9}} }[/math]
POT 4.67[math]\displaystyle{ \small{\times 10^{22}} }[/math]
Stopped mu/p 1.9[math]\displaystyle{ \small{\times 10^{-4}} }[/math] rough estimate, TBC, assumes stopped mu/kW same at 800 and 8000 MeV among possibly other things
SES <3[math]\displaystyle{ \small{\times 10^{-18}} }[/math]
E(conversion e-) 104.97 MeV
tau(muon) 864 ns
Lead stopping target
E(conversion e-) 94.9 MeV