Learn about Mu2e-II: Difference between revisions

From New MediaWiki Site
Jump to navigation Jump to search
No edit summary
No edit summary
Line 41: Line 41:
|-
|-
| Beam power || 100 || kW
| Beam power || 100 || kW
|-
| Number of bunches || 16 || (at 162.5 MHz)
|-
| Spill width || 100 || ns
|-
|-
!colspan="3" |Production target parameters
!colspan="3" |Production target parameters
Line 51: Line 55:
|-style="color: green;"
|-style="color: green;"
!colspan="3" |Aluminum stopping target
!colspan="3" |Aluminum stopping target
|-
| Number of bunches || 16 || (at 162.5 MHz)
|-
| Spill width || 100 || ns
|-
|-
| Spill period || 1693 || ns
| Spill period || 1693 || ns
Line 82: Line 82:
!colspan="3" | Calorimeter
!colspan="3" | Calorimeter
|-
|-
| Material || BaF<math>_2</math> ||
| Material || ||
|-
|-
| Energy resolution || 10% || %
| Energy resolution || 10% || %

Revision as of 17:57, 24 August 2020

Nominal Parameter values
Parameter Nominal value Units
PIP-II parameters
Beam energy (kinetic) 800 MeV
1.28[math]\displaystyle{ \small{\times 10^{-10}} }[/math] J
Particles/pulse 6.7[math]\displaystyle{ \small{\times 10^{12}} }[/math]
I_average in pulse 2 mA
Pulse length 550 [math]\displaystyle{ \small\mu }[/math]s
Pulse rep rate 20 Hz
Bunch pattern programmable
RF frequency 162.5 MHz
325 MHz
650 MHz
Mu2e-II parameters
Run time/yr 2[math]\displaystyle{ \small{\times 10^{7}} }[/math] s
Duration of run 3 yr
Total run time 6e7 s
Total linac reps 1.2[math]\displaystyle{ \small{\times 10^{9}} }[/math]
Extinction 1[math]\displaystyle{ \small{\times 10^{-11}} }[/math]
Beam power 100 kW
Number of bunches 16 (at 162.5 MHz)
Spill width 100 ns
Production target parameters
Material
Power deposition kW
Optimizable parameters for stopping target material
Aluminum stopping target
Spill period 1693 ns
Spills/linac rep 27770 approximate, at 20 Hz linac repetition rate
Protons/spill 1.4[math]\displaystyle{ \small{\times 10^{9}} }[/math]
POT 4.67[math]\displaystyle{ \small{\times 10^{22}} }[/math]
Stopped mu/p 1.9[math]\displaystyle{ \small{\times 10^{-4}} }[/math] rough estimate, TBC, assumes stopped mu/kW same at 800 and 8000 MeV among possibly other things
SES <3[math]\displaystyle{ \small{\times 10^{-18}} }[/math]
E(conversion e-) 104.97 MeV
tau(muon) 864 ns
Lead stopping target
E(conversion e-) 94.9 MeV
Tracker
Resolution at 100 MeV
Calorimeter
Material
Energy resolution 10% %
Time resolution < 500 ps
Radiation dose 10 kGy
[math]\displaystyle{ \small 1\times 10^{13} }[/math] n/cm[math]\displaystyle{ \small{^2} }[/math]/s
Cosmic Ray Veto
Trigger/DAQ
Event size 1 MB
Tape storage 14 PB/yr