Line 4: Line 4:
!Parameter  
!Parameter  
!Nominal value
!Nominal value
!Units
!Units, Comments
|-
|-
!colspan="3" |PIP-II parameters
!colspan="3" |PIP-II parameters
Line 14: Line 14:
| Particles/pulse || 6.7<math>\small{\times 10^{12}}</math> ||
| Particles/pulse || 6.7<math>\small{\times 10^{12}}</math> ||
|-
|-
| I_average in pulse || 2 || mA
| I_average in pulse || 2 || mA (5 mA peak)
|-
|-
| Pulse length || 550 || <math>\small\mu</math>s
| Pulse length || 550 || <math>\small\mu</math>s
Line 21: Line 21:
|-
|-
| Bunch pattern || programmable ||
| Bunch pattern || programmable ||
|-
| Peak bunch size || 0.8<math>\small{\times 10^8}</math> || (5 mA)
|-
| Bunch length || 4 || ps
|-
|-
| RF frequency || 162.5 || MHz
| RF frequency || 162.5 || MHz
Line 29: Line 33:
|-
|-
!colspan="3" |Mu2e-II parameters
!colspan="3" |Mu2e-II parameters
|-
| Bunch frequency || 81.25 || MHz (assumes 1/2 of 162.5 available)
|-
|-
| Run time/yr || 2<math>\small{\times 10^{7}}</math> || s
| Run time/yr || 2<math>\small{\times 10^{7}}</math> || s
Line 42: Line 48:
| Beam power || 100 || kW
| Beam power || 100 || kW
|-
|-
| Number of bunches || 16 || (at 162.5 MHz)
| Number of bunches || 8 || (at 81.25 MHz)
|-
|-
| Spill width || 100 || ns
| Spill width || 100 || ns

Revision as of 21:06, 28 August 2020

Nominal Parameter values
Parameter Nominal value Units, Comments
PIP-II parameters
Beam energy (kinetic) 800 MeV
1.28[math]\displaystyle{ \small{\times 10^{-10}} }[/math] J
Particles/pulse 6.7[math]\displaystyle{ \small{\times 10^{12}} }[/math]
I_average in pulse 2 mA (5 mA peak)
Pulse length 550 [math]\displaystyle{ \small\mu }[/math]s
Pulse rep rate 20 Hz
Bunch pattern programmable
Peak bunch size 0.8[math]\displaystyle{ \small{\times 10^8} }[/math] (5 mA)
Bunch length 4 ps
RF frequency 162.5 MHz
325 MHz
650 MHz
Mu2e-II parameters
Bunch frequency 81.25 MHz (assumes 1/2 of 162.5 available)
Run time/yr 2[math]\displaystyle{ \small{\times 10^{7}} }[/math] s
Duration of run 3 yr
Total run time 6e7 s
Total linac reps 1.2[math]\displaystyle{ \small{\times 10^{9}} }[/math]
Extinction 1[math]\displaystyle{ \small{\times 10^{-11}} }[/math]
Beam power 100 kW
Number of bunches 8 (at 81.25 MHz)
Spill width 100 ns
Production target parameters
Material
Power deposition kW
Optimizable parameters for stopping target material
Aluminum stopping target
Spill period 1693 ns
Spills/linac rep 27770 approximate, at 20 Hz linac repetition rate
Protons/spill 1.4[math]\displaystyle{ \small{\times 10^{9}} }[/math]
POT 4.67[math]\displaystyle{ \small{\times 10^{22}} }[/math]
Stopped mu/p 1.9[math]\displaystyle{ \small{\times 10^{-4}} }[/math] rough estimate, TBC, assumes stopped mu/kW same at 800 and 8000 MeV among possibly other things
SES <3[math]\displaystyle{ \small{\times 10^{-18}} }[/math]
E(conversion e-) 104.97 MeV
tau(muon) 864 ns
Lead stopping target
E(conversion e-) 94.9 MeV
Tracker
Resolution at 100 MeV
Calorimeter
Material
Energy resolution 10% %
Time resolution < 500 ps
Radiation dose 10 kGy
[math]\displaystyle{ \small 1\times 10^{13} }[/math] n/cm[math]\displaystyle{ \small{^2} }[/math]/s
Cosmic Ray Veto
Trigger/DAQ
Event size 1 MB
Tape storage 14 PB/yr