Learn about Mu2e-II
Jump to navigation
Jump to search
| Parameter | Nominal value | Units |
|---|---|---|
| PIP-II parameters | ||
| Beam energy (kinetic) | 800 | MeV |
| 1.28e-10 | J | |
| Particles/pulse | 6.7e12 | |
| I_average in pulse | 2 | mA |
| Pulse length | 550 | micro s |
| Pulse rep rate | 20 | Hz |
| Bunch pattern | programmable | |
| RF frequency | 162.5 | MHz |
| 325 | MHz | |
| 650 | MHz | |
| Mu2e-II parameters | ||
| Run time/yr | 2e7 | s |
| Duration of run | 3 | yr |
| Total run time | 6e7 | s |
| Total linac reps | 1.2e9 | |
| Extinction | 1e-11 | |
| Beam power | 100 | kW |
| Optimizable parameters for stopping target material | ||
| Aluminum stopping target | ||
| Number of bunches | 16 | (at 162.5 MHz) |
| Spill width | 100 | ns |
| Spill period | 1693 | ns |
| Spills/linac rep | 27770 | approximate, at 20 Hz linac repetition rate |
| Protons/spill | 1.4e9 | |
| POT | 4.67e22 | |
| Stopped mu/p | 1.9e-4 | rough estimate, TBC, assumes stopped mu/kW same at 800 and 8000 MeV among possibly other things |
| SES | <3e-18 | |
| E(conversion e-) | 104.97 | MeV |
| tau(muon) | 864 | ns |
| Lead stopping target | ||
| E(conversion e-) | 94.9 | MeV |